- High Efficiency Diamante Pro Ductless Mini Split Heat Pump System
- Cooling capacity: 12,000 BTU/H with 19 SEER2 / 10 EER2 efficiency
- Heating capacity: 12,200 BTU/H with 8.5 HSPF2 / 3.21 COP2 efficiency
- Voltage: 110/120V, 60Hz, 1Ph
- High Wall Mounted Air Conditioning & Heating System
- Variable Speed DC Inverter Operation Mode
- Low Ambient Unit (-13°F)
- AHRI Estimated Annual Operating Costs:
- Cooling: $79.00
- Heating: $254.00
Refrigerant
R410A Pre-Charged Outdoor Unit, accommodating refrigerant line lengths up to 25 ft. per circuit.
IMPORTANT NOTE
The copper tubing is included in the outdoor unit cardboard box and the communication wiring kit is included in the indoor unit cardboard box. This product set is comprised of 2 cartons only.
What's Included
- Indoor Unit
- Outdoor Unit
- Wireless Remote Control (with wall holder and batteries)
- 16 Ft. Copper Lines
- 16 Ft. Electrical Wire
- 10 Ft. Drain for indoor/outdoor
- Wall Passage Sleeve
- Putty for Wall Hole
- Leak Guard Sealer
- Wrapping Tape
- Installation Manual
- User’s Manual
Our Guarantee
- 5 years Warranty for Parts
- 5 years Warranty for Compressor
Features
- Dual Swing
- Dual Drainage
- Low Noise
- High Efficiency
Notes: See comparison table with WYS series
Technical Information
Performance Data
- Power Supply: 110~120V, 60Hz, 1Ph
- Cooling Rated Capacity: 12,000 BTU/h
- Cooling Capacity Range: 3,600~13,200 BTU/h
- Cooling SEER2: 19.0 BTU/W.h
- Cooling EER2: 10.0 BTU/W.h
- Heating Rated Capacity: 12,200 BTU/h
- Heating Capacity Range: 3,700~13,500 BTU/h
- Heating HSPF2 (Region IV/V): 8.5 / 7.2 BTU/W.h
- Heating C.O.P.2 (47°F/5°F): 3.21 / 1.75 W/W
- Refrigerant Type: R410A
- Suitable Area: 200~450 Sq.F
Indoor Unit Data
- Part Number: WT012ALFI19HLE
- Air Flow (Hi/Med/Lo): 383 / 318 / 253 CFM
- Sound Level (Hi/Med/Lo): 39 / 34 / 29 dB(A)
- Net Dimensions (WDH): 32 x 8-1/8 x 11-1/2 Inches
- Carton Dimensions (WDH): 34-7/8 x 11 x 14-3/8 Inches
- Net / Gross Weight: 19.8 / 26.5 lbs
Outdoor Unit Data
- Part Number: YN012ALFI19RPE
- Breaker Needed: 20A (single-pole)
- Sound Level: 52 dB(A)
- Net Dimensions (WDH): 28-1/8 x 11-1/2 x 19-5/8 Inches
- Carton Dimensions (WDH): 33 x 13-1/4 x 21-5/8 Inches
- Net / Gross Weight: 55 / 66.1 lbs
Manuals & Documents
Free Shipping For All Orders Over $49
For a Limited Time we offer free shipping on All Orders Above $49 by Standard Ground or delivered by Freight (LTL) to the 48 contiguous states. Free shipping offer does not apply to Alaska, Hawaii, or any international destination. Free shipping eligibility is noted on the product page, above the price.
Click here for information on Returns and Refunds
Shipping Details
We only ship to the 48 contiguous United States. No shipments to APO/FPO addresses, AK, HI, PR or other US Territories. No international shipments. Due to the size and the weight of our equipment, we can only utilize well known freight companies for shipping. Each shipment will be palletized, strapped down and wrapped in stretch film to protect against damages during transit.
Upon arrival you may ask the driver to break down the palette into individual cartons to unload the goods from the truck easily. We generally include Lift Gate service. This will arrive as curb side delivery. Trucker will unload the goods from the truck to ground level. If you must have inside delivery service, there will be an additional charge which needs to be paid separately and coordinated with the freight company. We also allow free pickup from our main distribution warehouse, located in Miami area. Equipment we sell is not suitable for express or courier shipping because of their weight as well as high risk of damages.
Due to higher than expected order volume and busy sales season, larger orders may take an extra 3-5 days to be prepared for shipment. We are working around-the-clock to ship out all orders in a timely manner, and will communicate with you if there are any unexpected delays or questions.
We prepare each shipment within 72 hours after the receipt of payment (only during weekdays). Trucking companies usually pick up same day or a day after we call them that the shipment is ready. The transit may take any time between 5 to 8 business days and in rare cases up to 12 days.
We will provide tracking information after shipment. Please contact us in case of any shipment delays. CHECK YOUR INFORMATION CAREFULLY TO SUBMIT THE CORRECT DELIVERY ADDRESS, UPDATED EMAIL AND A VALID PHONE NUMBER with your order. Someone must be present to receive the cargo at the time of delivery. Delivery company will call your phone number to setup a delivery appointment for residential deliveries. If your phone number is not valid, the cargo can not be delivered and will be returned at your expense within 3 days of arrival. If the delivery is refused or can not be delivered, it will be handled as returned merchandise.
Upon arrival, count all cartons and compare with the number stated on the delivery receipt before signing. Open the cartons and inspect the goods carefully for any damages. All products have been inspected under strict ISO regulated facilities and leave our warehouse in perfect condition. Report any shipping damages to the freight carrier on the delivery receipt and file a claim. Also contact us with the description of damages and pictures, etc. Although rare, certain freight damages can occur and we are here to help.
We carry all necessary replacement and service parts and components in large quantities and make them available during and after the warranty period.
QUESTIONS & ANSWERS
Ask a Question-
Can the air handler be mounted on the ceiling instead of on a vertical wall?
No it cannot. It must be on a vertical wall. We have a ceiling mount line (CYB series).
-
How cold can it get? The lowest temp on it?
This can be set to between 61° to 86°F. It will continue to provide heating down to -13°F outside temperatures.
-
How many amps should the dedicated circuit be?
20A, single-bus bar type.
-
How easy is it to flush the lines for a DIY installation?
Quite a simple process. Here is an instructional video on how to perform this step: https://www.youtube.com/watch?v=ZDXIIJwDkM8
-
How many amps on this unit? What gauge wire to run unit?
This would take a 20A breaker with 12 AWG wire.
-
What are the starting and running watts?
This is an inverter-type system with slow-start technology so starting watts are close to 0. Rated capacity input wattage is 1,070W. For more info see here: https://www.pdhvac.com/site/downloads/brochures/WYT-19-2020.pdf
-
How many square feet is this unit work for?
For standard applications, we recommend this particular unit for spaces between 200 and 450 square feet.
-
Does the unit use the remote as a thermostat?
Yes, that is correct.
-
Is there a listing as to what size room these units will provide for in square footage?
To figure out BTU needed per room we recommend our HVAC calculator.
Also check the tech brochure which has suggested square footages for each model. -
need 25 ft electrict line set
The Diamante series comes pre-packed with a 16 ft lineset which cannot be modified during purchase. If you need longer, it would require purchasing either the WYS series, or a longer lineset here.
-
What size circuit breaker does this require? Also, if I am using a fused disconnect what size fuse should I use?
This would take a 20A breaker. You can use a 30A disconnect alongside that.
-
Is this system fully charged so I don’t need special equipment to do the install
The way it works is that the outdoor condensing unit is pre-charged with R410a to support line lengths up to 25 ft long. You will need to remove the air from the lines before releasing the refrigerant from the outdoor unit, using a vacuum pump or the flushing kit that we sell.
-
Does the 115v unit require 12/2 or 12/3 wiring?
It would require 1 hot line, 1 neutral line, and one ground.
-
I can't seem to find the power draw of these units online, what is the amp draw for these units? Thanks.
Please see the full electrical and technical specs for this series here: https://www.pdhvac.com/site/downloads/brochures/WYT-19-2020.pdf
-
does this series have the "Vacation mode" where you can set a very low heating set point ( 45 deg) when unoccupied?
Yes it does, this is done by pressing the AH button on the remote.
-
Is this an inverter system
Yes, this is a heat pump and variable-speed inverter.
-
Can the line set be shortened?
Yes they can be cut and re-flared to the length you need.
-
Can outdoor unit installed horizontally?
No it cannot. It must be upright.
-
Would it be safe to run this from a modified sine wave inverter?
Yes that would be completely fine to do.